11. What are at least two instances where a splice is allowed to be made in underground consumer's service conductors?
Q: What is the maximum ampacity of a #8 copper conductor in a conduit with type THWN insulation used in…
A: The given conductor is conduit type #8 copper with THWN insulation, the ambient temperature of 50…
Q: 4. What terms describes an overcurrent protective device having an interrupting rating in compliance…
A: According to article 110.9 of the NEC, Circuit breaker describes an over-current protective device…
Q: 12. Which of the following statements about ground faults is true? A. They can happen if a…
A: Given Which of the following statements about ground faults is true? Mark the correct answer
Q: The insulation rating of class 3, PLTC, FPL, CM cables rated at ____ volts.
A: Ans. 300 volts
Q: Define the tunneling current.
A: A quantum mechanical phenomena known as tunneling. When electrons pass through a barrier that they…
Q: explain/describe given full wiring circuit for “Prototype-Electric” Vehicle System!
A: A wiring circuit of Prototype-Electric Vehicle system is given in the question. We need to explain…
Q: For installing directly in a concrete slab, (armored cable), (non metallic-sheated cable), (rigid…
A: For installing directly in a concrete slab Rigid metal conduit (RMC) can be used. A rigid metal…
Q: Determine the maximum number of convenience outlets of 2 plug for 15, 20, 25 and 30 circuit breaker
A: Circuit Breaker- Circuit breaker is a device which is used as a switch which breaks the circuit when…
Q: Describe what the following conductor designation means when it is printed on the insulation;…
A:
Q: When testing the twisted pair cable through cable tester, if the LED lights are jumping back and…
A: Cable Tester- Cable tester is a device which is used to test a cable. Cable tester detects the…
Q: Define cable rating in a built environment
A: Cable selection and application : It is essential to know cable construction, characteristics,…
Q: XLPE insulated high voltage underground cable will be installed along a street. The cable will then…
A: Given: XLPE insulated high voltage underground cable will be installed along a street. The cable…
Q: Which of the following statements about equipment grounding conductors (EGCs) is true? A. The…
A: Statement about the equipment grounding conductors (EGCs)
Q: Most residential general lighting circuits are wired with 14-AWG copper conductors and are protected…
A: Generally, the electricians follow the table wherein the calculated values of circuit breaker size…
Q: What assumptions can you make regarding the following receptacle wiring? Check all that apply.
A: A split pair is a wiring fault in which two twisted pair wires are linked instead with two wires…
Q: Which of the following would help avoid the choke effect in grounding electrode conductors? A.…
A: The correct option is B that us using an appropriate PVC(POLY VINY CHLORIDE) CONDUIT WILL AVOID…
Q: 1. What is the proper size copper grounding electrode conductor for a 100-ampere service that…
A: Given-Rating of service conductor=100 ASize of phase conductor= 3/0 AWG
Q: Which of the following statements about equipment grounding conductors is true? A. Unacceptable…
A: Correct option is B that is ELECTRIC GROUND CONDUCTORS must be capable of withstanding the higher…
Q: Assuming copper, standard wire type, and normal temperature rating, what is the typical conductor…
A: There is a standard table to know the conductor size (in AWG) in American Wire Gauge, which gives…
Q: List the methods by which an equipment grounding conductor is connected to a device box
A:
Q: What are Diagram,Construction, Operation, Advantages and Disadvantages of Air Circuit Breaker
A:
Q: 10.a. Which of the following is a condition of the exception that allows the grounded conductor of…
A: According to guidelines we need to solve only first question. According to the question we have to…
Q: Basically, ______receptacles are required to be installed if an equipment grounding conductor is…
A: Article 406 of NEC covers the installation of receptacles of both grounded type and non-grounded…
Q: What type of bonding jumper connects the grounded circuit conductor and the equipment grounding…
A: In a power system , Main bonding jumper connects the grounded circuit conductor and the equipment…
Q: Four 6 AWG THW Cu conductors are installed in the same conduit to supply fastened-in-place…
A: Given Ambient temperature =30 degree celcius three conductors are carrying current
Q: What are Diagram,Construction, Operation, Advantages and Disadvantages of Oil Circuit Breaker.…
A:
Q: What type of electrical conductor is used for underground applications?
A: Type SE or USE cables are used for underground application. This contain two or more conductors, is…
Q: A protective conductor connecting exposed conductive parts of equipment to the main earthing…
A: In earthing a conductor is used to connect the exposed conductive parts(metallic parts) of various…
Q: Which of the following is an installation requirement for the grounding electrode conductor in a…
A: ANSWER - (A,C,D) is correct EXPLANATION- Option (A)- Grounding…
Q: A set of conductors is used to supply residential unit with a total load current of 60 A at a…
A:
Q: Where insulated conductors are deflected within a wireway, either at the ends or where conduits,…
A:
Q: 14. If the total circular mil area of the largest ungrounded service-entrance conductor for a…
A: Explanation: The equivalent area of four ungrounded paralleled 500 kcmil conductors is 2000 kcmil.…
Q: Twenty-two 14 AWG copper conductors are run in conduit. Each conductor has type THHN insulation. the…
A: The given information is:
Q: 7. The size of the supply-side bonding jumpers for each of the individual raceways in the parallel…
A: NEC: NEC stands for National Electric Code. It is a regulatory body that set standard for safety…
Q: You have determined that a 4700-ohm, 1/2-watt resistor on an electronic circuit board is defective.…
A: Resistor=4700 ohm ,Power=0.5 W Current in the circuit; P=I2R0.5=I2×4700I=0.54700I=10.314 A
Q: Explain the relevance of earthing and bonding in an electrical Installation.
A: Earthing is used to protect us from an electric shock. It is done by providing a path (a protective…
Q: is the required size of THHN copper conductors for a feeder serving two 208Y/120V, four-wire,…
A:
Q: For residential wiring, not less than one 15-ampere lighting branch circuit should be provided for…
A: The National Electrical Code (NEC) is a regionally adoptable standard for the safe installation of…
Q: The copper line with a total length of 20 meters operates in the 220 volt city network. If three…
A:
Q: The voltage drop percentage for a panel feeder with a no continuous load of 180A, using 3/0 THWN…
A: Given data, A 3/0 THWN copper conductors at 480 V Length, L=248' Load current, I=180 A
Q: What size equipment grounding conductor is used with # 8 AWG nonmetallic-sheathed cable
A: The minimum size equipment grounding conductor is selected on the basis of the current rating…
Q: What is the smallest size conduit that can fit 13 #8 RWU90 conductors?
A: Given: 13 #8 RWU90 conductors The diameter of one cable of the #8 RWU90 conductor is 0.306 inches.…
Q: Terminals of switches and receptacles marked CO/ALR are suitable for use with _______________,…
A: The term CO/ALR is abbreviated as Copper Aluminium Revised. The switches are rated as 15 A and…
Step by step
Solved in 2 steps
- Most residential general lighting circuits are wired with 14-AWG copper conductors and are protected by 15-amp circuit breakers. However, there are many electricians who install 12-AWG copper conductors and protect them with 20-amp circuit breakers. How will you know which conductor size and which circuit breaker size will be used for the general lighting branch circuits in the house you are wiring?3. The three bus-bar conductors in an outdoor sub-station are supplied by units ofpost insulators. Each unit consists of a stack of 3-pin insulators fixed one on the top of the other. The voltage across the lowest insulator is 8-45 kV and that across the next is 7-25 kV. Find the bus-bar voltage of the station. [38-8 kV]5. Which of the following descriptions of a ground ring is correct?A. A ground ring is a circular formation that's made up of six or more grounding electrodes.B. A ground ring is a coiled conductor that's buried underneath a utility pole.C. A ground ring is a device that's used to clamp a conductor to a water pipe.D. A ground ring is a bare copper conductor that will encircle an entire structure underground.
- What is the maximum size Grounding Electrode Conductor regardless of the size of the service?7.B. The size of a grounding electrode conductor for a service or separately derived system is generally basedon the size of the largestA. ungrounded supply conductor.B. equipment grounding conductor.C. grounded electrode.D. bonding jumper.7.C. Which of the following statements about bonding is true?A. The joint or termination must offer opposition in the circuit for effective electrical connections.B. Effective bonding keeps impedance high if a fault should occur.C. The entire electrical safety circuit is only as good as its strongest bonded link.D. Bonding connections must endure high levels of fault current until overcurrent protective devices can operate.The following problems refer to grounding requirements. 1. What is the minimum size copper grounding electrode conductor for a service with three sets of parallel 350 kcmil conductors (three conductors per phase)?
- The following problems refer to grounding requirements. Give the source of yourresponses.1. What is the proper size copper grounding electrode conductor for a 100-ampere service that consists of 3/0 AWG ungrounded conductors?h.1. In an alternating-current system, the maximum size for a copper grounding electrode conductor isA. 250 kcmil.B. 3/0.C. 500 kcmil.D. 4/0. h.2. The figure shows a fault condition in an ungrounded electrical system. Which of the following will occurbecause of the fault in this system?A. Only the overcurrent protector at Point A will trip open.B. The ground fault will heavily damage the service.C. Nothing will happen until a second ground fault occurs.D. The overcurrent protection will trip, shutting off all the line side power.The three bus-bar conductors in an outdoor sub-station are supplied by units of post insulators. Each unit consists of a stack of 3-pin insulators fixed one on the top of the other. The voltage across the lowest insulator is 8-45 kV and that across the next is 7-25 kV. Find the bus-bar voltage of the station.
- What is the acceptable minimum value of leakage current of HI-POT Test of electrical cables. Can you explain which Standard that are commonly use. If it is posible show me the calculation on how we get the value of the lekage current.Electrical Engineering What is the smallest square box that will accommodate four No. 12 conductors and four No. 10 conductors if a. These conductors are pulled through without a splice? b. These conductors are all spliced in the box?Define an equipment grounding conductor.