12.7 The lateral force that is generated during building shaking can be calculated with the equation: Force = mass x acceleration, Based on this, which one of the following statement(s) is correct? ⚫ A building's total seismic design force is proportional to its weight. ⚫ Seismic forces are applied at the ground level; therefore, a building's upper floors have very small seismic force. ⚫ The largest seismic force is generated at the upper floors where they have the highest acceleration. . Seismic protective devises that dampen (reduce) building acceleration may be used to reduce the building seismic force. 12.8 Given five-story building, that weighs a 100kips and has concrete shear walls and special moment-resisting frames: a) Determine Response Modification Factor, R, from ASCE 7, Table 12.2-1 for Dual System of Special Moment Frame and Special reinforced concrete shear wall (Type D-3) b) Calculate Seismic Base Shear (V) using the following ASCE 7 equations and building information: SDS V = C₂W where C. is the lesser of Cs (R/1) and Cs SD1-1 T. R Accelerations (USGS maps): SDs = 1.1 Sp1 = 0.6 Building Period: T= 0.5 sec Importance Factor: le = 1.0 (commercial building) c) The architect has decided to eliminate the moment frames because the deep beams along the building perimeter reduce window openings. Determine the percent increase in base shear if the moment frames were eliminated and lateral resistance was provided with only a special reinforced concrete shear wall system (Type B-4 in ASCE Table 12.2-1)

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
Question
12.7 The lateral force that is generated during building shaking can be calculated with the equation: Force = mass x acceleration,
Based on this, which one of the following statement(s) is correct?
⚫ A building's total seismic design force is proportional to its weight.
⚫ Seismic forces are applied at the ground level; therefore, a building's upper floors have very small seismic force.
⚫ The largest seismic force is generated at the upper floors where they have the highest acceleration.
.
Seismic protective devises that dampen (reduce) building acceleration may be used to reduce the building seismic force.
12.8 Given five-story building, that weighs a 100kips and has concrete shear walls and special moment-resisting frames:
a) Determine Response Modification Factor, R, from ASCE 7, Table 12.2-1 for Dual System of Special Moment Frame
and Special reinforced concrete shear wall (Type D-3)
b) Calculate Seismic Base Shear (V) using the following ASCE 7 equations and building information:
SDS
V = C₂W
where C. is the lesser of Cs
(R/1)
and
Cs
SD1-1
T. R
Accelerations (USGS maps):
SDs = 1.1
Sp1 = 0.6
Building Period: T= 0.5 sec
Importance Factor: le = 1.0 (commercial building)
c) The architect has decided to eliminate the moment frames because the deep beams along the building perimeter reduce
window openings. Determine the percent increase in base shear if the moment frames were eliminated and lateral
resistance was provided with only a special reinforced concrete shear wall system (Type B-4 in ASCE Table 12.2-1)
Transcribed Image Text:12.7 The lateral force that is generated during building shaking can be calculated with the equation: Force = mass x acceleration, Based on this, which one of the following statement(s) is correct? ⚫ A building's total seismic design force is proportional to its weight. ⚫ Seismic forces are applied at the ground level; therefore, a building's upper floors have very small seismic force. ⚫ The largest seismic force is generated at the upper floors where they have the highest acceleration. . Seismic protective devises that dampen (reduce) building acceleration may be used to reduce the building seismic force. 12.8 Given five-story building, that weighs a 100kips and has concrete shear walls and special moment-resisting frames: a) Determine Response Modification Factor, R, from ASCE 7, Table 12.2-1 for Dual System of Special Moment Frame and Special reinforced concrete shear wall (Type D-3) b) Calculate Seismic Base Shear (V) using the following ASCE 7 equations and building information: SDS V = C₂W where C. is the lesser of Cs (R/1) and Cs SD1-1 T. R Accelerations (USGS maps): SDs = 1.1 Sp1 = 0.6 Building Period: T= 0.5 sec Importance Factor: le = 1.0 (commercial building) c) The architect has decided to eliminate the moment frames because the deep beams along the building perimeter reduce window openings. Determine the percent increase in base shear if the moment frames were eliminated and lateral resistance was provided with only a special reinforced concrete shear wall system (Type B-4 in ASCE Table 12.2-1)
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning