As shown in the figure, an air conditioner operating at steady state maintains a dwelling at 70°F on a day when the outside temperature is 102°F. The rate of heat transfer into the dwelling through the walls and roof is 30,000 Btu/h and the net power input to the air conditioner compressor is 3.4 hp. Inside, 70° F Evaporator 30.000 Btu Refrigerant loop W. Compressor Outside Condonsor mmo Determine the coefficient of performance of the air conditioner. Determine the power input required, in hp, and the coefficient of performance for a reversible air conditioner providing the same cooling effect while operating between the same cold and hot temperatures.

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter45: Domestic Refrigerators And Freezers
Section: Chapter Questions
Problem 2RQ: The operating condition for the single compressor in a household refrigerator is the lowest box...
icon
Related questions
Question
100%
As shown in the figure, an air conditioner operating at steady state maintains a dwelling at 70°F on a day when the outside
temperature is 102°F. The rate of heat transfer into the dwelling through the walls and roof is 30,000 Btu/h and the net power input to
the air conditioner compressor is 3.4 hp.
Inside, 70° F
Evaporator
← 30.000 Bu
Refrigerant loop
W.
Compressor
Outside
Condonsor
Que
Determine the coefficient of performance of the air conditioner. Determine the power input required, in hp, and the coefficient of
performance for a reversible air conditioner providing the same cooling effect while operating between the same cold and hot
temperatures.
Transcribed Image Text:As shown in the figure, an air conditioner operating at steady state maintains a dwelling at 70°F on a day when the outside temperature is 102°F. The rate of heat transfer into the dwelling through the walls and roof is 30,000 Btu/h and the net power input to the air conditioner compressor is 3.4 hp. Inside, 70° F Evaporator ← 30.000 Bu Refrigerant loop W. Compressor Outside Condonsor Que Determine the coefficient of performance of the air conditioner. Determine the power input required, in hp, and the coefficient of performance for a reversible air conditioner providing the same cooling effect while operating between the same cold and hot temperatures.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning