Calculate the total heat gain of a restaurant at its peak occupancy load at about 1PM. When hundred dinners and 15 employees are present, Given: Heat gain through wall and roof: 2500KJ/hr; Heat gain through glass areas:500KJ; Number of florescent tube lights:60; Rating of each tube light:40W; Rating of toasters inside space:2650W; Sensible heat gain per dinner: 250K¡/hr; Latent heat gain per dinner: 260K¡/hr Sensible heat per employee:305Kj/hr Latent heat per employee:545KJ/hr Inside design conditions:25 °C DB, 19°C WB Outside design conditions: 40 °C DB, 27 °CWB Ventilation requirement: 0.4cmm/person

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter44: Geothermal Heat Pumps
Section: Chapter Questions
Problem 12RQ: The function of the pressure tank in an open-loop, geo-thermal heat pump well system is to prevent...
icon
Related questions
Question
Calculate the total heat gain of a restaurant at its peak occupancy load at about 1PM. When hundred
dinners and 15 employees are present, Given:
Heat gain through wall and roof: 2500KJ/hr;
Heat gain through glass areas:500KJ;
Number of florescent tube lights:60;
Rating of each tube light:40W;
Rating of toasters inside space:2650W;
Sensible heat gain per dinner: 250K¡/hr;
Latent heat gain per dinner: 260K¡/hr
Sensible heat per employee:305Kj/hr
Latent heat per employee:545KJ/hr
Inside design conditions:25 °C DB, 19°C WB
Outside design conditions: 40 °C DB, 27 °CWB
Ventilation requirement: 0.4cmm/person
Transcribed Image Text:Calculate the total heat gain of a restaurant at its peak occupancy load at about 1PM. When hundred dinners and 15 employees are present, Given: Heat gain through wall and roof: 2500KJ/hr; Heat gain through glass areas:500KJ; Number of florescent tube lights:60; Rating of each tube light:40W; Rating of toasters inside space:2650W; Sensible heat gain per dinner: 250K¡/hr; Latent heat gain per dinner: 260K¡/hr Sensible heat per employee:305Kj/hr Latent heat per employee:545KJ/hr Inside design conditions:25 °C DB, 19°C WB Outside design conditions: 40 °C DB, 27 °CWB Ventilation requirement: 0.4cmm/person
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Convection
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning