Materials Needed semi-micro test tubes and rack solid I2 regular test tubes and rack squash pipettes solid CusO4-SH,0 food dye solid (NH4)½SO4 heavy metals waste container halogenated waste container non-halogenated waste container acetone суclohexane propan-2-ol Method Part A: Solubility of ionic and molecular solids Place a small amount (about the size of I grain of rice, see picture) of copper sulfate into cach of three DRY semi-micro test tubes. Add 20 drops of water to the first test tube and gently flick the test tube with your finger to ensure mixing. 1. 2. Repeat step I using acetone in place of water as the solvent in the second test tube. 3. Repeat step 2 replacing acetone with cyclohexane in the third test tube. Hold the test tubes against a white background to compare the solubility of copper sulfate in the three solvents and record your results. Discard these mixtures into the heavy metals waste container in the fume cupboard. Once these test tubes have been emptied you can re-use them in the next step without further cleaning. 4. 5. Repeat steps 1-4 but replace the copper sulfate with a tiny piece of solid iodine (I) in each of the test tubes. Discard these mixtures into the halogenated waste container in the fume cupboard. Complete the following table with regard to the solubility of cach substance in the various solvents. Water Acetone Cyclohexane Copper sulfate lodine

Chemistry: Principles and Practice
3rd Edition
ISBN:9780534420123
Author:Daniel L. Reger, Scott R. Goode, David W. Ball, Edward Mercer
Publisher:Daniel L. Reger, Scott R. Goode, David W. Ball, Edward Mercer
Chapter14: Chemical Equilibrium
Section: Chapter Questions
Problem 14.67QE
icon
Related questions
Question
Materials Needed
solid I2
solid CUSO4-5H20
food dye
solid (NH4)2SO4
heavy metals waste container
halogenated waste container
non-halogenated waste container
semi-micro test tubes and rack
regular test tubes and rack
squash pipettes
acetone
cyclohexane
propan-2-ol
Method
Part A: Solubility of ionic and molecular solids
1.
Place a small amount (about the size of 1 grain of rice, see picture) of copper sulfate into each of three DRY
semi-micro test tubes. Add 20 drops of water to the first test tube and gently flick the test tube with your
finger to ensure mixing.
2.
Repeat step 1 using acetone in place of water as the solvent in the second test tube.
3.
Repeat step 2 replacing acetone with cyclohexane in the third test tube.
Hold the test tubes against a white background to compare the solubility of copper sulfate in the three solvents
and record your results. Discard these mixtures into the heavy metals waste container in the fume cupboard.
Once these test tubes have been emptied you can re-use them in the next step without further cleaning.
4.
Repeat steps 1-4 but replace the copper sulfate with a tiny piece of solid iodine (I2) in each of the test tubes. Discard
these mixtures into the halogenated waste container in the fume cupboard.
5.
Complete the following table with regard to the solubility of each substance in the various solvents.
Water
Acetone
Cyclohexane
Copper
sulfate
lodine
Transcribed Image Text:Materials Needed solid I2 solid CUSO4-5H20 food dye solid (NH4)2SO4 heavy metals waste container halogenated waste container non-halogenated waste container semi-micro test tubes and rack regular test tubes and rack squash pipettes acetone cyclohexane propan-2-ol Method Part A: Solubility of ionic and molecular solids 1. Place a small amount (about the size of 1 grain of rice, see picture) of copper sulfate into each of three DRY semi-micro test tubes. Add 20 drops of water to the first test tube and gently flick the test tube with your finger to ensure mixing. 2. Repeat step 1 using acetone in place of water as the solvent in the second test tube. 3. Repeat step 2 replacing acetone with cyclohexane in the third test tube. Hold the test tubes against a white background to compare the solubility of copper sulfate in the three solvents and record your results. Discard these mixtures into the heavy metals waste container in the fume cupboard. Once these test tubes have been emptied you can re-use them in the next step without further cleaning. 4. Repeat steps 1-4 but replace the copper sulfate with a tiny piece of solid iodine (I2) in each of the test tubes. Discard these mixtures into the halogenated waste container in the fume cupboard. 5. Complete the following table with regard to the solubility of each substance in the various solvents. Water Acetone Cyclohexane Copper sulfate lodine
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Solutions
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Chemistry: Principles and Practice
Chemistry: Principles and Practice
Chemistry
ISBN:
9780534420123
Author:
Daniel L. Reger, Scott R. Goode, David W. Ball, Edward Mercer
Publisher:
Cengage Learning
Principles of Modern Chemistry
Principles of Modern Chemistry
Chemistry
ISBN:
9781305079113
Author:
David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:
Cengage Learning
EBK A SMALL SCALE APPROACH TO ORGANIC L
EBK A SMALL SCALE APPROACH TO ORGANIC L
Chemistry
ISBN:
9781305446021
Author:
Lampman
Publisher:
CENGAGE LEARNING - CONSIGNMENT
Chemistry & Chemical Reactivity
Chemistry & Chemical Reactivity
Chemistry
ISBN:
9781133949640
Author:
John C. Kotz, Paul M. Treichel, John Townsend, David Treichel
Publisher:
Cengage Learning
Chemistry & Chemical Reactivity
Chemistry & Chemical Reactivity
Chemistry
ISBN:
9781337399074
Author:
John C. Kotz, Paul M. Treichel, John Townsend, David Treichel
Publisher:
Cengage Learning
Introduction to General, Organic and Biochemistry
Introduction to General, Organic and Biochemistry
Chemistry
ISBN:
9781285869759
Author:
Frederick A. Bettelheim, William H. Brown, Mary K. Campbell, Shawn O. Farrell, Omar Torres
Publisher:
Cengage Learning