QUESTION 7 How can a sample be loaded into the melting point capillary tube? O Push the open end of the tube into the sample. Tap the tube against the lab countertop, closed-end-down. O Push the closed end of the tube into the sample. Tap the tube against the lab countertop, open-end-down. O Push the closed end of the tube into the sample. Tap the tube against the lab countertop, closed-end-down. O Push the open end of the tube into the sample. Tap the tube against the lab countertop, open-end-down. QUESTION 8 A student working next to you complains that their recrystallized sample has a broad melting range, usually about 50-59 °C. This is not close to the melting point of any possible unknowns they may have been assigned. What advice can you offer this student? O Use the higher end of this range, 59 °C, to estimate the melting point and try to identify your unknown based on that. O Use the lower end of this range, 50 °C, to estimate the melting point and try to identify your unknown based on that. O Your crystals may not be dried yet. Leave the crystals to dry for at least a day before checking the melting point again. O You are using too low of a heat ramp. Try a heat ramp of 2.0 or 5.0 to give the sample enough heat to melt properly. QUESTION 9 Unknown #5 and stearic acid both have a melting range of 69-71 °C. How can you describe unknown # 5? O Unknown #5 might be pure stearic acid. It could also be another compound with the same melting range as stearic acid. Unkonwn #5 can not possibly be stearic acid. O Unknown #5 is impure stearic acid. O Unkonwn #5 must be pure stearic acid and could not be anything else.

Macroscale and Microscale Organic Experiments
7th Edition
ISBN:9781305577190
Author:Kenneth L. Williamson, Katherine M. Masters
Publisher:Kenneth L. Williamson, Katherine M. Masters
Chapter38: Grignard Synthesis Of Triphenylmethanol And Benzoic Acid
Section: Chapter Questions
Problem 8Q
icon
Related questions
Question
7 8 9
2
3
QUESTION 7
W
4
5
21
How can a sample be loaded into the melting point capillary tube?
O Push the open end of the tube into the sample. Tap the tube against the lab countertop, closed-end-down.
O Push the closed end of the tube into the sample. Tap the tube against the lab countertop, open-end-down.
O Push the closed end of the tube into the sample. Tap the tube against the lab countertop, closed-end-down.
O Push the open end of the tube into the sample. Tap the tube against the lab countertop, open-end-down.
QUESTION 8
A student working next to you complains that their recrystallized sample has a broad melting range, usually about 50-59 °C. This is not close to the melting point of any possible
unknowns they may have been assigned. What advice can you offer this student?
O Use the higher end of this range, 59 °C, to estimate the melting point and try to identify your unknown based on that.
O Use the lower end of this range, 50 °C, to estimate the melting point and try to identify your unknown based on that.
O Your crystals may not be dried yet. Leave the crystals to dry for at least a day before checking the melting point again.
O You are using too low of a heat ramp. Try a heat ramp of 2.0 or 5.0 to give the sample enough heat to melt properly.
*3
6
QUESTION 9
Unknown #5 and stearic acid both have a melting range of 69-71 °C. How can you describe unknown #5?
O Unknown #5 might be pure stearic acid. It could also be another compound with the same melting range as stearic acid.
O Unkonwn # 5 can not possibly be stearic acid.
O Unknown #5 is impure stearic acid.
O Unkonwn # 5 must be pure stearic acid and could not be anything else.
Click Save and Submit to save and submit. Click Save All Answers to save all answers.
E
7
D
80
F3
8
$
4
888
F4
R
LL
F
10
%
S
x / c I v
X
C
V
5
T
G
#tv
MacBook Air
6
Fo
Y
B
&
Ve
7
H
A
ad
F7
5
*
N
00
8
DII
FB
J
1
(
9
F9
M
)
O
F10
Transcribed Image Text:2 3 QUESTION 7 W 4 5 21 How can a sample be loaded into the melting point capillary tube? O Push the open end of the tube into the sample. Tap the tube against the lab countertop, closed-end-down. O Push the closed end of the tube into the sample. Tap the tube against the lab countertop, open-end-down. O Push the closed end of the tube into the sample. Tap the tube against the lab countertop, closed-end-down. O Push the open end of the tube into the sample. Tap the tube against the lab countertop, open-end-down. QUESTION 8 A student working next to you complains that their recrystallized sample has a broad melting range, usually about 50-59 °C. This is not close to the melting point of any possible unknowns they may have been assigned. What advice can you offer this student? O Use the higher end of this range, 59 °C, to estimate the melting point and try to identify your unknown based on that. O Use the lower end of this range, 50 °C, to estimate the melting point and try to identify your unknown based on that. O Your crystals may not be dried yet. Leave the crystals to dry for at least a day before checking the melting point again. O You are using too low of a heat ramp. Try a heat ramp of 2.0 or 5.0 to give the sample enough heat to melt properly. *3 6 QUESTION 9 Unknown #5 and stearic acid both have a melting range of 69-71 °C. How can you describe unknown #5? O Unknown #5 might be pure stearic acid. It could also be another compound with the same melting range as stearic acid. O Unkonwn # 5 can not possibly be stearic acid. O Unknown #5 is impure stearic acid. O Unkonwn # 5 must be pure stearic acid and could not be anything else. Click Save and Submit to save and submit. Click Save All Answers to save all answers. E 7 D 80 F3 8 $ 4 888 F4 R LL F 10 % S x / c I v X C V 5 T G #tv MacBook Air 6 Fo Y B & Ve 7 H A ad F7 5 * N 00 8 DII FB J 1 ( 9 F9 M ) O F10
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Sample Preparation in Analytical Chemistry
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Macroscale and Microscale Organic Experiments
Macroscale and Microscale Organic Experiments
Chemistry
ISBN:
9781305577190
Author:
Kenneth L. Williamson, Katherine M. Masters
Publisher:
Brooks Cole
Chemistry for Engineering Students
Chemistry for Engineering Students
Chemistry
ISBN:
9781337398909
Author:
Lawrence S. Brown, Tom Holme
Publisher:
Cengage Learning