Question Two, 11 kV, 30 MVA 3-0 star connected generators operates in parallel. The positive, negative and zero sequence reactance of each being respectively, j0.16, j0.14, j0.08 p.u. The star point of one of the generators is isolated and that of the other is solidly grounded. Find the fault current for a fault impedance of j0.0892 for line to line fault on terminals of generators?
Question Two, 11 kV, 30 MVA 3-0 star connected generators operates in parallel. The positive, negative and zero sequence reactance of each being respectively, j0.16, j0.14, j0.08 p.u. The star point of one of the generators is isolated and that of the other is solidly grounded. Find the fault current for a fault impedance of j0.0892 for line to line fault on terminals of generators?
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter9: Unsymmetrical Faults
Section: Chapter Questions
Problem 9.13P: Consider the oneline diagram of a simple power system shown in Figure 9.20. System data in per-unit...
Related questions
Concept explainers
Synchronous Generator
In comparison to an asynchronous generator, it is a machine where the rotor speed is equal to the rotating magnetic field produced by the stator, i.e., mechanical speed is equal to the electrical speed, thus called synchronous, and not asynchronous.
Salient Pole Rotor
Salient pole rotor includes a large number of exposed poles mounted on a magnetic wheel. The construction of a bright pole is as shown in the image on the left. The proposed poles are made of metal laminations. The rotor winding is provided on these poles and is supported by pole shoes.
Question
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 3 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning