The full-load slip of 4-pole,60Hz,440v (line -to-line) three phase induction motor is 0.05.

i.What is the speed of the rotating stator field?What is the frequencey (in Hz) of the rotor current.

ii.When the output power of the motor is 90 hp at a speed of 1732rpm,rotational losses(which includes frictional and core losses) are 10,100W,while copper losses for both rotor and stator total 3700W.Determine the  motor efficiency and line current,assuming the motor has a 0.8 pf lagging under these conditions.

Expert Solution
steps

Step by step

Solved in 4 steps with 4 images