The value of the phase constant for the entire transmission line (BI) in degrees is:
Q: Transmission Line is connected in Nominal-Pi Circuit. Select one: True False
A:
Q: g) Why the Capacitance effect is neglected in Short Transmission Line.
A: As per the guidelines, we supposed to answer one question at a time so, please ask other question…
Q: b) Figure 2 shows the configuration of a single-phase two-conductor in the transmission line.…
A: Since you have asked multiple questions so we will solve the 2nd question for you. If you want any…
Q: Solve for the admittance, Yab (magnitude only)
A:
Q: -3-phase line conductor 3/5 E the dielectric strength of citical voltage for the line. actor mo=…
A:
Q: factor . The arrangement of conductors of a single-phase transmission line is shown below, the…
A:
Q: A lossless transmission line has a distributed inductance of 10 pH per meter and a distributed shunt…
A: Given data : Distributed inductance L=10×10-6H/m For 4m length L=10×10-6×4 =40×10-6 Distributed…
Q: a) Certain measurements made at 5 kHz on a half kilometer long transmission line. The results show…
A: Given, length of transmission line, l = 0.5 km Frequency, f = 5kHz Characteristic impedance, zo=…
Q: Load impedance 30 + j10(N)is connected to the lossless transmission line 0.101 A and characteristic…
A: Load impedance 30+j10 Ω is connected to the lossless transmission line 0.101 λ and characteristic…
Q: A sinusoidal voltage wave is propagating on a low loss transmission line. The voltage as a function…
A:
Q: Q3. For the Figure below, find the inductance per km of a transposed double circuit three - phase…
A: Inductance per km is determined as shown below
Q: A 3-phase transmission line has its conductors at the corners of an equilateral triangle with side…
A: Given, A 3 phase transmission line has its conductors at the corners of an equilateral triangle…
Q: When a lossless line is terminated with an arbitrary load impedance ZĻ, then it : a) causes wave…
A: Every transmission line has a characteristic impedance (Zo). Usually, a transmission line is always…
Q: For a one port network, explain the effect on the admittance frequency characteristics when it has a…
A: In the question, What is effect of frequency in admittance of path if Element is connected to…
Q: Consider the following statements: Surge impedance loading of a transmission line can be increased…
A: we need to explain how SIL can be increased.
Q: A lossless 60 ohm line is terminated by a 60+j60 ohm load .If Zin =120- j60ohm. How far (in term of…
A: The wave is function of space and time. The EM wave is formed when electric field is in contact with…
Q: In a mismatched transmission line with intrinsic impedance of Z, and with a load of impedance of Z,,…
A: A quarter-wave transformer is a basic impedance transformer used in impedance matching to reduce…
Q: Find the inductance/phase/km of a three-phase transmission line using 1.6 cm diameter conductors…
A:
Q: Find the inductance/phase/km of a three-phase transmission line using 1.3 cm diameter conductors…
A:
Q: Write a short note on each of the following 1) Propagation constant 2) Phase constant 3)…
A: Transmission line connection between the transmitter and receiver to permit signal transmission.…
Q: Q3. For the Figure below, find the inductance per km of a transposed double circuit three- phase…
A: Given, r=1.2 cm d1=7.5 mD=42+0.752=4.07 md2=42+7.5+0.752=9.17 md3=82+7.52=10.97 md4=7.5+0.75+0.75=9…
Q: Q6: Calculate Zin at the load using smith chart for total transmission lines, while the wavelength…
A:
Q: A 3-phase transmission line has its conductors at the corners of an equilateral triangle with side 3…
A: we need to find out inductance of the line per phase per km.
Q: 2) For a single solid conductor three phase transposed transmission line, if the r=0.0845 m and GMD…
A: Per phase capacitance =(2×pi×E0)/ln(GMD/GMR)
Q: In short transmission line calculations, the effects of the line capacitance are neglected because…
A:
Q: A lossless transmission line has a capacitance per unit length of 64pF/m and an inductance per unit…
A:
Q: Determine the primary constants, R, L, G, and C for a distortion-less line working at 300MHz. Given…
A: Given,Frequency, f=300 MHzCharacteristic impedance, Zo=75 ΩAttenuation constant, α=0.12 Np/mWave…
Q: A rectangular surge of 500 kV 3µs travels along the terminated line by an inductance of 2mH. If the…
A: Given Rectangular voltage magnitude vm=500 kvTime duration t=3 μsSurge impedance Z0=600…
Q: Long distance transmission lines often use higher voltages and higher frequencies, as this results…
A: For constant power transfer which is proportional to the product of voltage and current, in general…
Q: The transmission line has the following data weight of the conductor = 8.2 kg/m, working tension =…
A: sag in transmission line ,sag(s) = wl28T
Q: 7. A transmission line has the following per-unit-length parameters: L = 0.25 uH/m, C= 100 pF/m,…
A:
Q: A single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4…
A:
Q: Q6: Calculate Zin at the load using smith chart for total transmission lines, while the wavelength…
A:
Q: In medium transmission line, capacitance is considered as O a. Lumped parameter O b. Distributed…
A: Given : Generally depending on the type of the medium we classify them parameters. Distributed…
Q: A 3-phase transmission line using 20 mm diameter conductor. When these conductors are placed at the…
A: Given that d = 20mm r = 10mm = 0.01 m D = 2.5 m 3 phase
Q: Q3. For the Figure below, find the inductance per km of a transposed double circuit three- phase…
A:
Q: Find the inductance/phase/km of a three-phase transmission line using 1.5 cm diameter conductors…
A: We can use all the derived formulas for Inductance of transmission line for 3phase conductor
Q: 10. The capacitance per unit length and the characteristic impedance of a lossless transmission line…
A:
Q: Answer all subpart I will thumbs up... Consider a three-phase single circuit transmission line 362…
A: R = 0.1069 ohm/km L = 1.3549 mH/km C = 0.0085 microfarad/km G = 0 transmission line = 362 km long VR…
Q: In line capacitance is neglected due to Select one: O a. Short transmission line, smaller length and…
A: The question is from transmission and distribution topic.
Q: The voltage regulation of a short transmission line is estimated: O a. Only on Line Inductance O b.…
A: At the point when a transmission line is conveying current, there is a voltage drop in the line…
Q: A 1-phase transmission line has two parallel conductors 1.5 meters apart, the diameter of each…
A: Given transmission line is single phase transmission line. The distance between two conductors is…
Q: A transmission line has a characteristic impedance of 300 N and is terminated in a load of 300 -…
A:
Q: When analyzing Short Transmission Lines, it is assumed that the Sending and Receiving Ends should be…
A: A short transmission line has an effective length less than 80 km. The line charging current is…
Q: The input impedance of a 75Ω lossless transmission line is measured to be (150- j75Ω) at 0.21λ away…
A: It is given that: Zo=75 ΩZin=150-j75 Ωl=0.21 λ
Q: A lossless transmission line (TL) has a characteristic impedance of Zo= 250 N, a load impedance of…
A: Note: As per our calculations, I have solved the first three subparts. Given data: Zo=250…
Q: Coaxial cable of an infinite produces reflection coefficient of – 0.3 + j0.4 when terminated in a…
A: Given: Coaxial cable of an infinite produces reflection coefficient of (-0.3+j0.4) when terminated…
Q: A lossless vacuum-filled transmission line of characteristic impedance R. = 1000 is terminated by a…
A:
Q: a) A line has a characteristic impedance of 307.70 and a termination resistance of 600n. Assume that…
A: Note: Since you have posted a question with multiple subparts, we will solve the first three…
Trending now
This is a popular solution!
Step by step
Solved in 2 steps with 2 images
- The instantaneous power absorbed by the load in a single-phase ac circuit, for a general R LC load under sinusoidal-steady-state excitation. is (a) Nonzero constant (b) Zero (c) Containing double-frequency componentsProblem 4- A large 3-phase industrial load draws 3.6 MVA at 0.85 power factor lagging from through a three- phase 12.47/7.2 kV 3-wire overhead distribution line. The phase conductor is #1 ACSR “Robin". Taking 3.6 MVA and 12.47 kV as base values, determine (a) The base impedance in (N) (b) The reactive power drawn by the load (p.u.) (c) The total current (p.u.) drawn from the power supplyParagraph Styles The power factor must be close to in the transmission lines will be reduced To insure that losses D(Ctrl) -
- A surge of 100 kV travels along an overhead line towards its junction with a cable. The surge impedance for the overhead line and cable are 400 ohms and 50 ohms respectively. The magnitude of the surge transmitted through the cable is ?There is an installation with two equal triphasic loads of 300 kVA each and a power factor of 0.9 lagging. When connecting a pure reactive element in parallel, the reactive power at the entrance of the installation is 150 kVARS, with a lagging power factor. We can say that: a) A bank of reactors was connected and the fp deteriorated. b) A capacitor bank was connected and the pf deteriorated. c) A bank of reactors was connected and the fp improved. d) A capacitor bank was connected and the pf improved. e) None of the aboveAn inductive circuit draws a line current of 10A. If the reactive component of the line current is 6A, then power factor of the circuit is ___ . a. 0.6 lagging b. 0.857 lagging c. 0.5 lagging d. 0.5 leading
- The impedance per phase of a 3-phase transmission line on a base of 100 MVA and 100 kV is 2 p.u. The value of this impedance on a base of 400 MVA and 400 kV would be?Give example problems for impedances and admittance.A three-phase balanced load of 15A per phase is supplied by a steel wire armoured cable with a c.s.a. of 2.5mm². The voltage drop for this cable is 15mv/A/m and the circuit is 40m long. Calculate the voltage drop in the cable.
- Subject - Design electrical circuits for single phase AC networks Question - Compare the effect of varying resistance, capacitance and inductance in a pararllel and series AC circuits on voltage resistance and impedance.Quest- A single phase 50 Hz, system supplies an inductive load of 5000 kw at power factor 0.8 lag through a line 25 km. Resistance of the line is 0.0195 2/km and inductance = 0.36 mH/km, receiving end voltage is 10 kV. A capacitor is connected across the load to get the voltage regulation of 10%. Ratio of transmission line loss with and without shunt capacitor isPlease help with this balanced three-phase circuit problem.