Three parallel three-phase loads are supplied from a 207.85-V rms, 60-Hz three-phase supply. The loads are as follows: Load 1: A 15 HP motor operating at full-load, and 0.6 lagging power factor. Load 2: A balanced resistive load that draws a total of 6 kW. Load 3: A Y-connected capacitor bank with a total rating of 16 kvar. (a) What is the total system kW, kvar, power factor, and the supply current per phase? (b) What is the system power factor and the supply current per phase when the resistive load and induction motor are operating but the capacitor bank is switched off?

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.33P: Consider the three single-phase two-winding transformers shown in Figure 3.37. The high-voltage...
icon
Related questions
Question
Three parallel three-phase loads are supplied from a 207.85-V rms, 60-Hz three-phase supply. The loads
are as follows:
Load 1: A 15 HP motor operating at full-load, and 0.6 lagging power factor.
Load 2: A balanced resistive load that draws a total of 6 kW.
Load 3: A Y-connected capacitor bank with a total rating of 16 kvar.
www
(a) What is the total system kW, kvar, power factor, and the supply current per phase?
(b) What is the system power factor and the supply current per phase when the resistive load and
induction motor are operating but the capacitor bank is switched off?
Transcribed Image Text:Three parallel three-phase loads are supplied from a 207.85-V rms, 60-Hz three-phase supply. The loads are as follows: Load 1: A 15 HP motor operating at full-load, and 0.6 lagging power factor. Load 2: A balanced resistive load that draws a total of 6 kW. Load 3: A Y-connected capacitor bank with a total rating of 16 kvar. www (a) What is the total system kW, kvar, power factor, and the supply current per phase? (b) What is the system power factor and the supply current per phase when the resistive load and induction motor are operating but the capacitor bank is switched off?
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 7 steps

Blurred answer
Knowledge Booster
Analysis of Single Phase and Three Phase System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning