Two loads are connected in parallel to a 1000 v(rms) 60Hz source. One of the loads has an average power of 500 kW and a forward power factor of 0.9. Since the other load absorbs 400kw and 600kvar power a) Draw the equivalent circuit of the system b) Find the common power factor of the system c) Find the value of the capacitor to be connected parallel to the loads so that the power factor is 0.95 back d) Find and compare the magnitude of the current drawn from the .source for the situations before and after the capacitor is connected

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.7P: Let a 100V sinusoidal source be connected to a series combination of a 3 resistor, an 8 inductor,...
icon
Related questions
Question
Two loads are connected in parallel to a 1000 v(rms) 60Hz source. One of
the loads has an average power of 500 kW and a forward power factor of
0.9. Since the other load absorbs 400kw and 600kvar power
a) Draw the equivalent circuit of the system
b) Find the common power factor of the system
c) Find the value of the capacitor to be connected parallel to the loads so
that the power factor is 0.95 back
d) Find and compare the magnitude of the current drawn from the
.source for the situations before and after the capacitor is connected
Transcribed Image Text:Two loads are connected in parallel to a 1000 v(rms) 60Hz source. One of the loads has an average power of 500 kW and a forward power factor of 0.9. Since the other load absorbs 400kw and 600kvar power a) Draw the equivalent circuit of the system b) Find the common power factor of the system c) Find the value of the capacitor to be connected parallel to the loads so that the power factor is 0.95 back d) Find and compare the magnitude of the current drawn from the .source for the situations before and after the capacitor is connected
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Source transformation method
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning