Voltage unbalance is the unbalance that occurs when the voltages at different motor terminals are not equal. This is a big problem for power companies generating, and other facilities using three phase power. If left in this condition this can cause transformer and motor windings to prematurely burn open. Using a DMM you are troubleshooting a 480 volt, 3 phase power feeding a fused disconnect connected to a 3 phase, 1 H.P. motor. Your findings are as follows: Phase A/B = 441 volts, Phase A/C = 479 volts and Phase B/C = 457 volts Find the voltage unbalance and determine if this is acceptable.
Voltage unbalance is the unbalance that occurs when the voltages at different motor terminals are not equal. This is a big problem for power companies generating, and other facilities using three phase power. If left in this condition this can cause transformer and motor windings to prematurely burn open. Using a DMM you are troubleshooting a 480 volt, 3 phase power feeding a fused disconnect connected to a 3 phase, 1 H.P. motor. Your findings are as follows: Phase A/B = 441 volts, Phase A/C = 479 volts and Phase B/C = 457 volts Find the voltage unbalance and determine if this is acceptable.
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.56P: Three single-phase two-winding transformers, each rated 3kVA,220/110volts,60Hz, with a 0.10 per-unit...
Related questions
Question
Voltage unbalance is the unbalance that occurs when the voltages at different motor terminals are not equal. This is a big problem for power companies generating, and other facilities using three phase power. If left in this condition this can cause transformer and motor windings to prematurely burn open. Using a DMM you are troubleshooting a 480 volt, 3 phase power feeding a fused disconnect connected to a 3 phase, 1 H.P. motor. Your findings are as follows:
Phase A/B = 441 volts, Phase A/C = 479 volts and Phase B/C = 457 volts
Find the voltage unbalance and determine if this is acceptable.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning