You are insulating a metal pipe carrying a hot fluid. The outside Diameter of the pipe is 3.5 cm, and the pipe has a length of 7.7 meters. Due to the fluid inside the pipe, the outside surface of the metal fluid pipe is kept at a constant temperature of 85.0°C. The metal pipe is inserted inside of a thin-wall circular tube, which has an inside diameter of 11.2 cm (ignore the resistance of the thin-wall circular tube). The space between the outside of the hot metal pipe and the inside of the thin-wall circular tube is filled with foam insulation, k = 0.036 W/m-K. The outside of the thin-walled circular tube is kept at a constant temperature of 28.0°C. Due to a manufacturing error, the metal pipe was not centered inside the thin-wall tube when the foam insulation was added, but was instead installed with an eccentricity of 2.0 cm (i.e. the center of the metal pipe is 2.0 cm distance from the center of the thin-walled circular tube). Calculate the increase in the heat transfer rate due to this manufacturing error.

College Physics
11th Edition
ISBN:9781305952300
Author:Raymond A. Serway, Chris Vuille
Publisher:Raymond A. Serway, Chris Vuille
Chapter1: Units, Trigonometry. And Vectors
Section: Chapter Questions
Problem 1CQ: Estimate the order of magnitude of the length, in meters, of each of the following; (a) a mouse, (b)...
icon
Related questions
Question
You are insulating a metal pipe carrying a hot fluid. The outside Diameter of the pipe is 3.5 cm, and the pipe has a length of 7.7 meters. Due to the fluid inside the pipe, the outside surface of the metal fluid pipe is kept at a constant temperature of 85.0°C. The metal pipe is inserted inside of a thin-wall circular tube, which has an inside diameter of 11.2 cm (ignore the resistance of the thin-wall circular tube). The space between the outside of the hot metal pipe and the inside of the thin-wall circular tube is filled with foam insulation, k = 0.036 W/m-K. The outside of the thin-walled circular tube is kept at a constant temperature of 28.0°C. Due to a manufacturing error, the metal pipe was not centered inside the thin-wall tube when the foam insulation was added, but was instead installed with an eccentricity of 2.0 cm (i.e. the center of the metal pipe is 2.0 cm distance from the center of the thin-walled circular tube). Calculate the increase in the heat transfer rate due to this manufacturing error.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
College Physics
College Physics
Physics
ISBN:
9781305952300
Author:
Raymond A. Serway, Chris Vuille
Publisher:
Cengage Learning
University Physics (14th Edition)
University Physics (14th Edition)
Physics
ISBN:
9780133969290
Author:
Hugh D. Young, Roger A. Freedman
Publisher:
PEARSON
Introduction To Quantum Mechanics
Introduction To Quantum Mechanics
Physics
ISBN:
9781107189638
Author:
Griffiths, David J., Schroeter, Darrell F.
Publisher:
Cambridge University Press
Physics for Scientists and Engineers
Physics for Scientists and Engineers
Physics
ISBN:
9781337553278
Author:
Raymond A. Serway, John W. Jewett
Publisher:
Cengage Learning
Lecture- Tutorials for Introductory Astronomy
Lecture- Tutorials for Introductory Astronomy
Physics
ISBN:
9780321820464
Author:
Edward E. Prather, Tim P. Slater, Jeff P. Adams, Gina Brissenden
Publisher:
Addison-Wesley
College Physics: A Strategic Approach (4th Editio…
College Physics: A Strategic Approach (4th Editio…
Physics
ISBN:
9780134609034
Author:
Randall D. Knight (Professor Emeritus), Brian Jones, Stuart Field
Publisher:
PEARSON