Chapter 10, Problem 10.1P

In a heat exchanger, as shown in the accompanying figure, air flows over brass tubes of 1.8-cm 1D and 2.1-cm OD containing steam. The convection heat transfer coefficients on the air and steam sides of the tubes are 70 W/m 2 K and 210 W/m 2 K , respectively. Calculate the overall heal transfer coefficient for the heal exchanger (a) based on the inner tube area and (b) based on the outer tube area.

Chapter 10, Problem 10.1P, 
10.1 In a heat exchanger, as shown in the accompanying figure, air flows over brass tubes of 1.8-cm

(a)

Expert Solution
Check Mark
To determine

The overall heat transfer coefficient based on the inner tube area.

Answer to Problem 10.1P

Over all heat transfer co-efficient based on inner surface area is 58.75 W/m2K

Explanation of Solution

Given information:

Inner diameter of the tube Di=1.8 cm=0.018 m

Outer diameter of the tube Do=2.1 cm=0.021m

Air flows outside the tubes and steam flows inside the tubes.

Convective heat-transfer coefficients onair side and steam side are ho=70 W/m2K and

hi=210 W/m2K

From Appendix 2 (Table 10),

Thermal conductivity of brass k=111 W/mK

Part a:

Over all hear transfer co-efficient based on inner surface area.

Over all heat transfer co-efficient based on inner surface area is given by (refer to Equation 10.4 in text book)

Ui=11hi+[Ailn(Ro/Ri)2πkL]+AiAoho

Ai=  Inside surface area of the tube =πDiL

Ao=  Outside surface area of the tube =πDoL

Ui=11hi+[πDiLln(Ro/Ri)2πkL]+πDiLπDoLho

Ui=11hi+[Diln(Do/Di)2k]+DiDoho

Ui=1[1210]+[0.018ln(0.0210.018)2×111]+[0.0180.021×70]

Ui=58.75 W/m2K

(b)

Expert Solution
Check Mark
To determine

Overall heat transfer coefficient based on outer surface area of the tube

Answer to Problem 10.1P

Overall heat transfer coefficient based on outer surface area of the tube is 50.36 W/m2K

Explanation of Solution

Overall heat transfer coefficient based on outer surface area of the tube is given by (refer to equation 10.3 in text book)

Uo=1[AoAihi]+[Ao*ln(Ro/Ri)2πkL]+[1ho]

Uo= 1[πDoLπDiLhi]+[πDoL*ln(Do/Di)2πkL]+[1ho]

Uo= 1[DoDihi]+[Doln(Do/Di)2k]+[1ho]

Uo=1[0.0210.018×210]+[0.021*ln(0.0210.018)2×111]+[170]

Uo=50.36 W/m2K

Overall heat transfer coefficient based on inner surface area is 50.36 W/m2K.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
Your second customer wants to choose a parallel-flow-plate-type heat exchanger that contains two fluids (oil and water) separated by a thin metal sheet as shown in figure 1 for cooling the lubricating oil. The heat exchanger is insulated by a 130-mm glass fiber insulation (paper faced, 28 kg/m3 ). The heat transfer coefficients of water and oil are 1200 and 900 W/m2 °C, respectively. Figure 1: A parallel-flow-plate-type heat exchanger. Your task to help your costumer by doing the following steps: STEP 1 The flow rate of cooling water is 0.2 kg/s, and the flow rate of oil the is 0.1 kg/s. Also, the oil and water enter at temperatures of 100 and 30°C, respectively, and the outlet temperature of the oil is 40°C. If the top surface of the heat exchanger is exposed to an atmospheric air (T=10°C) that is parallel to the flows and maintains a heat transfer coefficient of h = 70 W/m2 .K, which includes the effects of radiation, help your customer to calculate the heat…
a one shell and two tube pass heat exchanger, coolant enters the tube at 4.81 kg/s (spread over 72 tubes with each tube being 0.01 m in diameter and 1.95 m length) at an initial temperature of 25 C. Water enters the shell at 2.5 kg/s at an initial temperature of 5 C. The average convection coefficient of the water is known to be 1e4 W/m2.K. What is the overall heat transfer coefficient, assuming no fouling, negligible tube thermal resistance and near-identical inner and outer tube surfaces? What is the actual heat transfer rate? What is the coolant outlet temperature? The coolant properties are Cp = 1040 J/kg.K, μ = 7.65e-4 kg/s.m, k = 0.058 W/m.K and Pr = 14. Assume the water Cp = 4200 J/kg.K.
Calculate the rate of overall heat transfer coefficient for the tube heat exchanger withinner and outer heat transfer coefficient of 670 W/m2 -K and 1880 W/m2 -K, respectively.Thermal conductivity of the tube wall is 27 W/m-K. The diameter and the thickness of thetube are 4 cm and 1.5 mm, respectively. Then, calculate the rate of heat transfer for the tube heatexchanger per meter length if the temperatures of inner and outer surfaces are 100°Cand 52°C, respectively.
Knowledge Booster
Background pattern image
Mechanical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Principles of Heat Transfer (Activate Learning wi...
Mechanical Engineering
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Cengage Learning
Heat Transfer – Conduction, Convection and Radiation; Author: NG Science;https://www.youtube.com/watch?v=Me60Ti0E_rY;License: Standard youtube license