A private developer proposes to install a synchronous type generating plant connected to the local 11 kV network. If the generating plant produces 14 MW operating at 0.97 lagging power factor, calculate: (i) the reverse power flow into the transmission line during the peak loading conditions (11 kV bus is now the sending end) (ii) the corresponding per-unit voltage at the 11 kV busbar. If all factory loads are disconnected (e.g., due to a fault, or servicing) and if the generating plant continues to produce active power output of 14 MW, calculate the reactive power output of the generating plant required to keep the voltage rise at the 11 kV busbar within the statutory limit of +6 % of the nominal voltage.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
A private developer proposes to install a synchronous type generating
plant connected to the local 11 kV network. If the generating plant
produces 14 MW operating at 0.97 lagging power factor, calculate:
(i)
the reverse power flow into the transmission line during the
peak loading conditions (11 kV bus is now the sending end);
(ii)
the corresponding per-unit voltage at the 11 kV busbar.
If all factory loads are disconnected (e.g., due to a fault, or servicing)
and if the generating plant continues to produce active power output of
14 MW, calculate the reactive power output of the generating plant
required to keep the voltage rise at the 11 kV busbar within the
statutory limit of +6 % of the nominal voltage.
Transcribed Image Text:A private developer proposes to install a synchronous type generating plant connected to the local 11 kV network. If the generating plant produces 14 MW operating at 0.97 lagging power factor, calculate: (i) the reverse power flow into the transmission line during the peak loading conditions (11 kV bus is now the sending end); (ii) the corresponding per-unit voltage at the 11 kV busbar. If all factory loads are disconnected (e.g., due to a fault, or servicing) and if the generating plant continues to produce active power output of 14 MW, calculate the reactive power output of the generating plant required to keep the voltage rise at the 11 kV busbar within the statutory limit of +6 % of the nominal voltage.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,