Note: I need the expert's solution in handwriting with a signature or an equation with a relationship. Q1: Choose the correct answer 1- A single-phase transformer is rated at 220/22 V, 110 VA at 50 Hz, the turn ratio is: (a) 10 (b) 0.1 (c) 2 (d) 0.5 2- The direction of rotation of the de shunt motor can be reversed by (a) Reversing the polarity for both the armature winding and the field winding (b) Reversing the supply voltage connections (c) Reversing the polarity for either the field winding or the armature winding (d) None of these 3- The speed of a de motor can be controlled by varying (a) Its flux per pole (b) Resistance of armature circuit (c) Applied voltage (d) All of the above 4- The efficiency of a transformer is maximum when (a) Constant losses = Iron losses (b) Variable losses = Copper losses (c) Core losses = Copper losses (d) Constant losses = Core Losses 5-The No-load characteristics of a de shunt generator is also called: (a) The performance characteristics (b) The voltage regulation characteristics (c) Total characteristics (d) Magnetizing characteristics 6- The reason for the fall of the terminal voltage due to a load of a de shunt generator: (a) Armature resistance drop (b) Armature reaction drop (c) Reduction in field current (d) All the above

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Note: I need the expert's solution in handwriting with a signature or an equation with a relationship. Electric machines.
Note: I need the expert's solution in handwriting with a signature or an equation with
a relationship.
Q1: Choose the correct answer
1- A single-phase transformer is rated at 220/22 V, 110 VA at 50 Hz, the turn ratio is:
(a) 10
(b) 0.1
(c) 2
(d) 0.5
2- The direction of rotation of the de shunt motor can be reversed by
(a) Reversing the polarity for both the armature winding and the field winding
(b) Reversing the supply voltage connections
(c) Reversing the polarity for either the field winding or the armature winding
(d) None of these
3- The speed of a de motor can be controlled by varying
(a) Its flux per pole
(b) Resistance of armature circuit
(c) Applied voltage
(d) All of the above
4- The efficiency of a transformer is maximum when
(a) Constant losses = Iron losses
(b) Variable losses = Copper losses
(c) Core losses = Copper losses
(d) Constant losses = Core Losses
5-The No-load characteristics of a de shunt generator is also called:
(a) The performance characteristics
(b) The voltage regulation characteristics
(c) Total characteristics
(d) Magnetizing characteristics
6- The reason for the fall of the terminal voltage due to a load of a de shunt
generator:
(a) Armature resistance drop
(b) Armature reaction drop
(c) Reduction in field current
(d) All the above
Transcribed Image Text:Note: I need the expert's solution in handwriting with a signature or an equation with a relationship. Q1: Choose the correct answer 1- A single-phase transformer is rated at 220/22 V, 110 VA at 50 Hz, the turn ratio is: (a) 10 (b) 0.1 (c) 2 (d) 0.5 2- The direction of rotation of the de shunt motor can be reversed by (a) Reversing the polarity for both the armature winding and the field winding (b) Reversing the supply voltage connections (c) Reversing the polarity for either the field winding or the armature winding (d) None of these 3- The speed of a de motor can be controlled by varying (a) Its flux per pole (b) Resistance of armature circuit (c) Applied voltage (d) All of the above 4- The efficiency of a transformer is maximum when (a) Constant losses = Iron losses (b) Variable losses = Copper losses (c) Core losses = Copper losses (d) Constant losses = Core Losses 5-The No-load characteristics of a de shunt generator is also called: (a) The performance characteristics (b) The voltage regulation characteristics (c) Total characteristics (d) Magnetizing characteristics 6- The reason for the fall of the terminal voltage due to a load of a de shunt generator: (a) Armature resistance drop (b) Armature reaction drop (c) Reduction in field current (d) All the above
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,