Question
Chapter 1, Problem 1R
To determine
Mention the code that sets the standards for
Expert Solution & Answer
Answer to Problem 1R
The code that sets the standards for electrical installation work is NEC.
Explanation of Solution
Discussion:
The National Electrical Code (NEC) is the basic standard code and it sets the standards for electrical installation work. The NEC safeguards the persons and property from hazards during the usage of electricity.
The local and state electrical regulations and codes should also be considered along with the NEC for electrical installation work.
Conclusion:
Thus, the code that sets the standards for electrical installation work is NEC.
Want to see more full solutions like this?
Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
Grounding Lighting Fixtures. There are specific requirements for grounding lighting fixtures. How must they be grounded and with what size conductors? Be sure and cite the code in your answers.
Question 7
This question related to power system analysis.
Please make sure that the solution is clear and detailed.
Electrical plants
Define the terms "Main column ." " Line ." " Protection earth " and "
Operating earth
Chapter 1 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 1 - Prob. 1RCh. 1 - Prob. 2RCh. 1 - Does the NEC provide minimum or maximum standards?...Ch. 1 - What do the letters UL signify?Ch. 1 - What section of the NEC states that all listed or...Ch. 1 - Prob. 6RCh. 1 - Prob. 7RCh. 1 - Does compliance with the NEC always result in an...Ch. 1 - Name two nationally recognized testing...Ch. 1 - Prob. 10R
Ch. 1 - Prob. 12RCh. 1 - A junction box on a piece of European equipment is...Ch. 1 - Prob. 14RCh. 1 - You will learn in Chapter 3 that residential...Ch. 1 - Prob. 16RCh. 1 - What can you do to reduce or eliminate the...Ch. 1 - What is the NEC definition of a qualified person?Ch. 1 - Are low-voltage systems totally safe? Explain.Ch. 1 - Prob. 21RCh. 1 - What do the letters PPE stand for?...Ch. 1 - Prob. 23RCh. 1 - Where might you obtain information about...Ch. 1 - Prob. 25R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 1.1 PV modules can be wired together in an array using ______ connections to increase voltage. a. Terminating b. Series c. Parallel d. AC 1.2 A PV module, also called a solar panel, is comprised of individual photovoltaic _______ wired and mounted together as an integrated unit. a. Capsules b. Compartments c. Chips d. Cells 1.3 A __________ system uses a storage system that stores the generated electricity so it can provide during times when the system’s panels are not receiving solar energy. a. Direct coupled b. Self regulating c. Charge controlled d. Indirectly connected 1. 4 __________ energy may have the potential to supply all of the world's energy needs, but at this time, it provides a very small percentage. a. Coal b. Natural Gas c. Diesel d. Solararrow_forward7.A. Ferrous metal raceways or enclosures are made with _______ content.A. steel or brassB. aluminum or ironC. brass or aluminumD. iron or steel7.B. The size of a grounding electrode conductor for a service or separately derived system is generally basedon the size of the largestA. ungrounded supply conductor.B. equipment grounding conductor.C. grounded electrode.D. bonding jumper.7.C. Which of the following statements about bonding is true?A. The joint or termination must offer opposition in the circuit for effective electrical connections.B. Effective bonding keeps impedance high if a fault should occur.C. The entire electrical safety circuit is only as good as its strongest bonded link.D. Bonding connections must endure high levels of fault current until overcurrent protective devices can operate.arrow_forwardWhat follows is a numeric fill in the blank question with 3 blanks. Figure 1 shows the three phases V-t graph in Turkey. Please write the indicated values with their units in boxes and Voltage - time function of each phase in table below. Please write the units in the second box. 1= _______________ V 2= ________________ms 3= _______________msarrow_forward
- 24. The National Electrical Code® _____ contains tables dealing with conductors for general wiring. Select one: A. 100 B. 110 C. 310 D. 300arrow_forwardQ34 Provide answers for the following: a) Differentiate between Planned preventive maintenance and condition based maintenance. b) List the condition monitoring tests used for: i. Circuit breakers ii. iv. Transformers Cables, and Busbars (need two examples for each category).arrow_forward1. Alternating current systems of less than _______ volts are required to be grounded if they're installed outside as overhead conductors. A. 50 B. 100 C. 75 D. 120arrow_forward
- ____ current occurs when the system neutral is grounded improperly downstream from the service equipment. Select one: A. PHASED B. OBJECTIONABLE C. POSITIVE D. NEGATIVEarrow_forward13.a. What does Section 230.10 prohibit the use of for the support of overhead service conductors?A. Balcony railingsB. Trees and other types of vegetationC. Wooden fencingD. Lampposts 13.b. Section 230.6 establishes five conditions under which conductors can be physically located within abuilding or structure but can be considered _______ for the purposes of applying the Code requirements.A. protectedB. enabledC. chargedD. outsidearrow_forward7.B. The size of a grounding electrode conductor for a service or separately derived system is generally basedon the size of the largestA. ungrounded supply conductor.B. equipment grounding conductor.C. grounded electrode.D. bonding jumper.7.C. Which of the following statements about bonding is true?A. The joint or termination must offer opposition in the circuit for effective electrical connections.B. Effective bonding keeps impedance high if a fault should occur.C. The entire electrical safety circuit is only as good as its strongest bonded link.D. Bonding connections must endure high levels of fault current until overcurrent protective devices can operate.arrow_forward
- For high-voltage protection, fuses are generally preferable to circuit breakers for all of the following reasons except _. A. Cost b. Reliability c. Maintenance requirements d. Easier reset.arrow_forwardOn site plans, all evevations are referenced from_. A. The centerline of a street B. Ground level C. A bench mark D. A test boringarrow_forward6. Ferrous metal raceways or enclosures are made with _______ content.A. brass or aluminumB. steel or brassC. aluminum or ironD. iron or steelarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Types of House Wiring - Types of Electrical Wiring - Electrical Wiring; Author: Learning Engineering;https://www.youtube.com/watch?v=A5P-buWX-dA;License: Standard Youtube License