Whether is it necessary to add air-conditioner load and electric heating load to obtain the combined load on the system.
a.
Answer to Problem 1R
No, it is not necessary to add air-conditioner load and electric heating load to obtain the combined load on the system.
Explanation of Solution
Description:
From NEC 220.60, it is not necessary to add air-conditioner load and electric heating load to obtain the combined load on the system.
Conclusion:
No, it is not necessary to add air-conditioner load and electric heating load to obtain the combined load on the system.
b.
Explain the reason why it is not necessary to add air-conditioner load and electric heating load to obtain the combined load on the system.
b.
Explanation of Solution
Description:
The National Electrical Code (NEC) is the basic standard code and it sets the standards for
From NEC 220.60, the noncoincident loads such as electric heating and air-conditioner are not operated at the same time. Therefore, when calculating the feeder value that is used to supply both the loads, the larger value of loads can be considered.
Therefore, it is not necessary to add air-conditioner load and electric heating load to obtain the combined load on the system.
Conclusion:
Thus, the reason why it is not necessary to add air-conditioner load and electric heating load to obtain the combined load on the system is explained.
Want to see more full solutions like this?
Chapter 23 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
- 2. Imagine that you're asked to install an auxiliary grounding electrode at the base of a lighting pole in aparking lot. This auxiliary grounding electrode will be connected to theA. lighting pole's electrical service equipment grounding conductor.B. electrical service's grounding electrode conductor.C. next lighting pole's auxiliary grounding electrode.D. lighting pole's neutral conductor.arrow_forwardQUESTION 9 When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true? a A.This would be approved by code as the gas pipe is only being bonded to the electrical system. b B.This installation would be approved by code, as the gas pipe is not a grounding electrode. c C.Both A and B d D.Neither A nor Barrow_forwardAirframe Electrical System Question: What is the maximum acceptable voltage drop from the voltage source to the utilization equipment's ground in a 28 volt system? (Source: FAA AC 43.13-1B/2B)arrow_forward
- - Loads, Service, and Overcurrent Protection 6.a. The general lighting load is based on a _______ per square foot basis.A. kilowattB. number of circuitsC. volt-ampereD. general illumination6.b. What's the primary disadvantage of using copper conductors?A. AvailabilityB. WeightC. CostD. Durabilityarrow_forward7.A. Ferrous metal raceways or enclosures are made with _______ content.A. steel or brassB. aluminum or ironC. brass or aluminumD. iron or steel7.B. The size of a grounding electrode conductor for a service or separately derived system is generally basedon the size of the largestA. ungrounded supply conductor.B. equipment grounding conductor.C. grounded electrode.D. bonding jumper.7.C. Which of the following statements about bonding is true?A. The joint or termination must offer opposition in the circuit for effective electrical connections.B. Effective bonding keeps impedance high if a fault should occur.C. The entire electrical safety circuit is only as good as its strongest bonded link.D. Bonding connections must endure high levels of fault current until overcurrent protective devices can operate.arrow_forwardIf two 115-volt loads were connectedin parallel with 240 volts, they would__________.a. burn dimlyb. immediately burn outc. burn correctlyd. none of the abovearrow_forward
- 1. Alternating current systems of less than _______ volts are required to be grounded if they're installed outside as overhead conductors. A. 50 B. 100 C. 75 D. 120arrow_forward6.a. Extreme _______ may cause some nonmetallic conduits to become brittle and therefore moresusceptible to damage from physical contact.A. coldB. corrosionC. voltageD. heat6.b. Snap switches are permitted to be grouped or ganged in an enclosure provided the voltage between theadjacent snap switches does not exceed ___ V.A. 400B. 300C. 200D. 100arrow_forward___________ is an Area on a device characteristic where the ratio between applied voltage and resulting current is constant.arrow_forward
- 4.a. The ___ calculated load is rarely placed on an electrical system.A. optionalB. standardC. total 4.b. What's the primary disadvantage of using copper conductors?A. CostB. AvailabilityC. Weight 4.c. You're evaluating the components of a multioccupancy building that won't have an on-site employee. Tobe compliant with the NEC, each occupant will need to have access to their ownA. service-disconnecting means.B. service conductor.C. cable attachment point.D. emergency fire water-pump disconnect.arrow_forwardFollow the procedures in troubleshooting the defects and faults of an electric fan by filling in the missing steps.Doesn't rotate 1.___________ 2.____________ Check for Open AC cord or wiring3. ___________4.___________ Defective switch/electronic system control 5. _____________Defective module (system control).arrow_forwardAfter reduction, the current - caring capacity of a condenser is referred to as the___. A. ambience b. Allowable ampacity c. ampacity d. ambient ratingarrow_forward
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT