Structural Steel Design (6th Edition)
Structural Steel Design (6th Edition)
6th Edition
ISBN: 9780134589657
Author: Jack C. McCormac, Stephen F. Csernak
Publisher: PEARSON
Question
Book Icon
Chapter 6, Problem 6.1PFS
To determine

The selection of the lightest available W12 section to support the axial compression loads.

Expert Solution & Answer
Check Mark

Answer to Problem 6.1PFS

W12 x 65

Explanation of Solution

Given data:

PD=150kipsPL=230kipsLC=18ftSteelused=A992,Grade50

LRFD method:

The factored load is given by

Pu=1.2PD+1.6PLwhere,PuisfactoredloadPDisaxialcompressiondeadloadPLisaxialcompressionliveload

Substituting the values,

Pu=1.2(150)+1.6(230)Pu=548k

Assume slenderness ratio as

KLr=60

From table 4-14 in the AISC manual,

Corresponding to yield stress, Fy=50ksi and slenderness ratio, KLr=60 , the critical stress is

ϕcfcr=34.6ksi

The required area is

Areq=Puϕcfcrwhere,AreqisrequiredareaPuisfactoredloadϕcfcriscriticalstress

Substituting the values,

Areq=54834.6Areq=15.84in.2

Try section W12×58 .

From table 1-1 in the AISC manual,

The properties of the trial section are

Area,A=17.0in.2Minimumradiusofgyration,rmin=2.51in.

The slenderness ratio is

λ=Lcrminwhere,λisslendernessratioLciseffectivelengthofcolumnrminisminimumradiusofgyration

Substituting the values,

λ=18×122.51λ=86.06

From table 4-14 in the AISC manual,

Corresponding to yield stress, Fy=50ksi and slenderness ratio, KLr=86 , the critical stress is

ϕcfcr=26.2ksi

Corresponding to yield stress, Fy=50ksi and slenderness ratio, KLr=87 , the critical stress is

ϕcfcr=25.9ksi

By interpolation, the critical stress for Fy=50ksi and slenderness ratio KLr=86.06 is

ϕcfcr=26.2+25.926.28786(86.0686)ϕcfcr=26.182ksiϕcfcr=26.18ksi

The load-carrying capacity of the section is

ϕcPn=A×ϕcfcrwhere,ϕcPnisavailableloadcarryingcapacityAisareaofsectionϕcfcriscriticalstress

Substituting the values,

ϕcPn=17×26.18ϕcPn=445.06kϕcPn<Pu445.06k<548k

The load-carrying capacity of the trial section W12×58 is less than the required capacity. Hence, the section is not safe.

Try section W12×65 .

From table 1-1 in the AISC manual,

The properties of the trial section are

Area,A=19.1in.2Minimumradiusofgyration,rmin=3.02in.

The slenderness ratio is

λ=Lcrmin

Substituting the values,

λ=18×123.02λ=71.52

From table 4-14 in the AISC manual,

Corresponding to yield stress, Fy=50ksi and slenderness ratio, KLr=71 , the critical stress is

ϕcfcr=31.1ksi

Corresponding to yield stress, Fy=50ksi and slenderness ratio, KLr=72 , the critical stress is

ϕcfcr=30.8ksi

By interpolation, the critical stress for Fy=50ksi and slenderness ratio KLr=71.52 is

ϕcfcr=31.1+30.831.17271(71.5271)ϕcfcr=30.944ksiϕcfcr=30.94ksi

The load-carrying capacity of the section is

ϕcPn=A×ϕcfcr

Substituting the values,

ϕcPn=19.1×30.94ϕcPn=590.954kϕcPn=590.95kϕcPn>Pu590.95k>548k

The load-carrying capacity of the trial section W12×65 is more than the required capacity. Hence, the section is safe.

Therefore, use section W12×65 in LRFD method.

ASD method:

The factored load is given by

Pa=PD+PLwhere,PaisfactoredloadPDisaxialcompressiondeadloadPLisaxialcompressionliveload

Substituting the values,

Pa=150+230Pa=380k

Assume slenderness ratio as

KLr=60

From table 4-14 in AISC manual,

Corresponding to yield stress, Fy=50ksi and slenderness ratio, KLr=60 , the critical stress is

fcrΩc=23ksi

The required area is

Areq=PafcrΩcwhere,AreqisrequiredareaPaisfactoredloadfcrΩciscriticalstress

Substituting the values,

Areq=38023Areq=16.52in.2

Try section W12×58 .

From table 1-1 in the AISC manual,

The properties of the trial section are

Area,A=17.0in.2Minimumradiusofgyration,rmin=2.51in.

The slenderness ratio is

λ=Lcrminwhere,λisslendernessratioLciseffectivelengthofcolumnrminisminimumradiusofgyration

Substituting the values,

λ=18×122.51λ=86.06

From table 4-14 in the AISC manual,

Corresponding to yield stress, Fy=50ksi and slenderness ratio, KLr=86 , the critical stress is

fcrΩc=17.4ksi

Corresponding to yield stress, Fy=50ksi and slenderness ratio, KLr=87 , the critical stress is

fcrΩc=17.2ksi

By interpolation, the critical stress for Fy=50ksi and slenderness ratio, KLr=86.06 is

fcrΩc=17.4+17.217.48786(86.0686)fcrΩc=17.388ksifcrΩc=17.39ksi

The load-carrying capacity of the section is

PnΩc=A×fcrΩcwhere,PnΩcisavailableloadcarryingcapacityAisareaofsectionfcrΩciscriticalstress

Substituting the values,

PnΩc=17×17.39PnΩc=295.63kPnΩc<Pa295.63k<380k

The load-carrying capacity of the trial section W12×58 is less than the required capacity. Hence, the section is not safe.

Try section W12×65 .

From table 1-1 in the AISC manual,

The properties of the trial section are

Area,A=19.1in.2Minimumradiusofgyration,rmin=3.02in.

The slenderness ratio is

λ=Lcrmin

Substituting the values,

λ=18×123.02λ=71.52

From table 4-14 in the AISC manual,

Corresponding to yield stress, Fy=50ksi and slenderness ratio, KLr=71 , the critical stress is

fcrΩc=20.7ksi

Corresponding to yield stress, Fy=50ksi and slenderness ratio, KLr=72 , the critical stress is

fcrΩc=20.5ksi

By interpolation, the critical stress for Fy=50ksi and slenderness ratio KLr=71.52 is

fcrΩc=20.7+20.520.77271(71.5286)71fcrΩc=20.596ksifcrΩc=20.60ksi

The load-carrying capacity of the section is

PnΩc=A×fcrΩc

Substituting the values,

PnΩc=19.1×20.60PnΩc=393.46kPnΩc>Pa393.46k>380k

The load-carrying capacity of the trial section W12×65 is more than the required capacity. Hence, the section is safe.

Therefore, use section W12×65 in ASD method.

Conclusion:

Select the section W12×65 in both the LRFD method and ASD method.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
For Problem 1 b) - change the question to what is the axial stress of the wire.   Please show FBD and complete solutions.
Q3: The cantilevered bar in the Fig 3 is made from a cast iron material and is statically loaded with Fy - 250 Ibf and Fx= Fz-0. if the material is cast iron, the tensile ultimate strength is 32 kpsi and the compressive ultimate strength is 110 kpsi. Suk A- Analyze the stress situation in the small diameter at the shoulder at A (determine the maximum normal and shear stresses) considering the stress concentration at point A. B- Find the factor of safety based on Coulomb Mohr failure model R CM) 63 Sue Sut 32 C14) 16U5) 71 Fig.3 S063.6+5821.6
10 mm | | | | 10 mm 50 mm ارت - 50 mm 10 mm 20 kN B 150 mm 910 mm 10 kN D ------- 150 mm Two vertical forces are applied to a am of the cross section sh vn. Determine the maximum tensile and compressive stresses in portion BC of the beam.Show your complete solution and box your answer.
Knowledge Booster
Background pattern image
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Steel Design (Activate Learning with these NEW ti...
Civil Engineering
ISBN:9781337094740
Author:Segui, William T.
Publisher:Cengage Learning