Q1.An industrial load can be supplied on the following alternative tariffs. (a) H.V. supply at Rs. 70 per kVA per annum plus 5 p per kWh (b) L.V. supply at Rs 75 per kVA per annum plus 6 p per kWh (c) Transformers and switchgear suitable for the HV supply cost Rs 60 per KVA, the full load transformation losses being 3%. The fixed charges are 20% per annum on the capital cost of the H.V. plant and the installation works at full load. If there are 50 working weeks in a year find the number of working hours p week above which the H.V. supply is cheaper. Assume a load of 2000 kW at unity power factor.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.33P: Consider the three single-phase two-winding transformers shown in Figure 3.37. The high-voltage...
icon
Related questions
Question
Q1.An industrial load can be supplied on the following alternative tariffs.
(a) H.V. supply at Rs. 70 per kVA per annum plus 5 p per kWh
(b) L.V. supply at Rs 75 per kVA per annum plus 6 p per kWh
(c) Transformers and switchgear suitable for the HV supply cost Rs 60 per kVA, the full load transformation
losses being 3%. The fixed charges are 20% per annum on the capital cost of the H.V. plant and the
installation works at full load. If there are 50 working weeks in a year find the number of working hours per
week above which the H.V. supply is cheaper. Assume a load of 2000 kW at unity power factor.
Transcribed Image Text:Q1.An industrial load can be supplied on the following alternative tariffs. (a) H.V. supply at Rs. 70 per kVA per annum plus 5 p per kWh (b) L.V. supply at Rs 75 per kVA per annum plus 6 p per kWh (c) Transformers and switchgear suitable for the HV supply cost Rs 60 per kVA, the full load transformation losses being 3%. The fixed charges are 20% per annum on the capital cost of the H.V. plant and the installation works at full load. If there are 50 working weeks in a year find the number of working hours per week above which the H.V. supply is cheaper. Assume a load of 2000 kW at unity power factor.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Types of Power Station and Its Characteristics
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning