The amount of caffeine in an analgesic tablet was determined by HPLC using a normal calibration curve. Standard solutions of caffeine were prepared and analyzed using a 10-uL fixed-volume injection loop. Results for the standards are summarized in the following table. Concentration, ppm 50.0 Peak Area 8 354 100.0 16 925 150.0 25 218 200.0 33 584 250.0 42 002 The sample was prepared by placing a single-analgesic tablet in a small beaker and adding 10 mL of methanol. After allowing the sample to dissolve, the contents of the beaker, including the insoluble binder, were quantitatively transferred to a 25-mL volumetric flask and diluted to volume with methanol. The sample was then filtered, and a l.00-mL aliquot was transferred to a 10-mL volumetric flask and diluted to volume with methanol. When analyzed by HPLC, the signal for the caffeine was found to be 21 469. Report the parts per million of caffeine in the analgesic tablet.

Chemistry
9th Edition
ISBN:9781133611097
Author:Steven S. Zumdahl
Publisher:Steven S. Zumdahl
Chapter11: Properties Of Solutions
Section: Chapter Questions
Problem 109AE: Patients undergoing an upper gastrointestinal tract laboratory test are typically given an X-ray...
icon
Related questions
Question
100%
The amount of caffeine in an analgesic tablet was determined by HPLC using a normal calibration curve.
Standard solutions of caffeine were prepared and analyzed using a 10-uL fixed-volume injection loop. Results
for the standards are summarized in the following table.
Concentration, ppm
Peak Area
8 354
16 925
25 218
50.0
100.0
150.0
200.0
33 584
250.0
42 002
The sample was prepared by placing a single-analgesic tablet in a small beaker and adding 10 mL of methanol.
After allowing the sample to dissolve, the contents of the beaker, including the insoluble binder, were
quantitatively transferred to a 25-mL volumetric flask and diluted to volume with methanol. The sample was then
filtered, and a 1.00-mL aliquot was transferred to a 10-mL volumetric flask and diluted to volume with methanol.
When analyzed by HPLC, the signal for the caffeine was found to be 21 469. Report the parts per million of
caffeine in the analgesic tablet.
Transcribed Image Text:The amount of caffeine in an analgesic tablet was determined by HPLC using a normal calibration curve. Standard solutions of caffeine were prepared and analyzed using a 10-uL fixed-volume injection loop. Results for the standards are summarized in the following table. Concentration, ppm Peak Area 8 354 16 925 25 218 50.0 100.0 150.0 200.0 33 584 250.0 42 002 The sample was prepared by placing a single-analgesic tablet in a small beaker and adding 10 mL of methanol. After allowing the sample to dissolve, the contents of the beaker, including the insoluble binder, were quantitatively transferred to a 25-mL volumetric flask and diluted to volume with methanol. The sample was then filtered, and a 1.00-mL aliquot was transferred to a 10-mL volumetric flask and diluted to volume with methanol. When analyzed by HPLC, the signal for the caffeine was found to be 21 469. Report the parts per million of caffeine in the analgesic tablet.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 1 images

Blurred answer
Knowledge Booster
Quality Assurance and Calibration Methods
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781133611097
Author:
Steven S. Zumdahl
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry: An Atoms First Approach
Chemistry: An Atoms First Approach
Chemistry
ISBN:
9781305079243
Author:
Steven S. Zumdahl, Susan A. Zumdahl
Publisher:
Cengage Learning
Chemistry: The Molecular Science
Chemistry: The Molecular Science
Chemistry
ISBN:
9781285199047
Author:
John W. Moore, Conrad L. Stanitski
Publisher:
Cengage Learning
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage